Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/07/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER ELECTRICAL |
|
| 04/06/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. CHECK WIRE FILL IN BOXES 2. USE PROPER CRIMP TOOLS ON SLEEVES. 3. USE WIRE NUTS PER INSTRUCTIONS FOR MAXIMUM CONDUCTORS. 4. FINISH WIRING FOR PORCH LIGHT. 5. CLAMPS FOR ROMEX ARE OVER TIGHTENED 6. SHEATHING FOR ROMEX NEEDS TO ENTER BOXES 7. GROUND ALL METAL BOXES 8. NAIL PLATE PROPERLY (COVER ALL STUD AREA). |