Permit: T06CM00327

Parcel: 140294810


Addresses:

3857 E SUN VIEW CT


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM00327

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/27/2006 FRAMING Approved IVRS - Inspection :*
09/26/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER OFFICE (H. LEYVA)
09/21/2006 FRAMING Partial Approval IVRS - Inspection :*
1) REPAIR AND SEAL STUCCO AT MECHANICAL PENETRATIONS
2) FILL DWV
3) NAIL OFF FHA STRAPS, AT STAIRS
4) REPAIR LINE SET INSULATION
09/14/2006 FRAMING Cancelled IVRS - RI canceled
09/01/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOT READY WITH ITEMS BELOW
B-VENT MISSING FOR W/H SUPPORT TRAP FOR
2ND FLOOR TUB
08/29/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) VACUUM BREAK REQUIRED AT HOSE BIB
2) SEAL LATHE AT SMART BOX AND ALL PENETRATIONS
3) FILL DWV
4) FIRE STOP IN GARAGE AT ENTRY POP-OUT
5) FIRE STOP 2ND FLOOR PEN.
6) WIRE CUT AT KITCHEN HALF-WALL
7) RPS STRAP REQUIRED AT OVER NOTCHED PLATE UNDER STAIRS
8) INSUFFICIENT NAILS IN STRAP AT TOP OF STAIRS
9) FIRE STOP AT SUPPLY DUCT THROUGH FLOOR
10) FIRE STOP GARAGE ATTIC IN 2ND FLOOR BATH
11) FIRE STOP 2ND FLOOR CHASE S.W. CORNER
12) A/C COPPER INSULATION DAMAGED OVER STAIRS
13) COMPLETE MECH BLOCKING