Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/01/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) SHEAR PROBLEM AT 2ND FLOOR BEAM ABOVE GARAGE TALK WITH CLAYTON ON HOW TO FIX |
|
| 04/26/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 4 X 6 POST IN KITCHEN 2) PROVIDE HANGER CONVERSIONS 3) CLIP ALL BEARING STUDS 4) H2.5 ON JOISTS AT INTERIOR BEAING WALLS PER PLAN 5) COMPLY WITH DETAIL 18/D1 6) INSTALL HOLDOWNS |
|
| 04/25/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RETRO HD W. SIDE OF GARAGE 2) COMPLETE SHEAR NAILING AT 8'-WEST SIDE 3) PROVIDE STEP LADDER TO INSPECT BEAM/POST CONNECTIONS-BACK PATIO 4) BANG PLATE PLUMBING BOTTOM PLATE 5) H2.5 FRONT PORCH RAFTERS 6) BLOCK/NAIL SHEARWALL AT WATER SERVICE 7) STOPPED INSPECTION-TOO MANY ITEMS |