Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/21/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/20/2006 EXT METAL CLIPS/EXT SHEATHING Cancelled
04/17/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 2, 4 AND 5
2) NO ROOF ACCESS
04/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ANCHOR BOTTOM PLATE OF SK1 3 PER PLAN
2) INTERIOR SHEAR WALLS MUST BE DBL TOP PLATED WITH SHEAR TRANSFER AND PROPER ANCHORS
3) TRIPPLE STUD UNDER GIRDER
4) PRESSURE BLOCKS NOT TIGHT
5) GABLE END HINGE BRACING NOT PER PLAN
6) STOPPED INSPECTION