Permit: T06CM00301

Parcel: 136155010

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM00301

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/02/2006 FRAMING Approved IVRS - Inspection :*
06/01/2006 FRAMING Partial Approval 1) PENDING PLUMBING
2) FILL DWV WATER TEST
3) OK TO INSULATE
05/31/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE ALL ITEMS FROM PRIOR INSPECTION
2) NO DWV WATER TEST
05/30/2006 FRAMING Partial Approval IVRS - Inspection :*
1) NEED SOUTH ROOF OVERHANG FIRE RATED
2) REMOVE RECEPTACLE UNDER BREAKFAST BAR TOP
3) NEED 12" CLEAR PEX TO CAN LIGHTS IN KITCHEN
4) LEAK IN ABS CEILING OF POWDER ROOM
5) SUPPORT ABS EVERY 4'
6) NEED 1" CLEAR TO COMBUSTIBLES ON B-VENTS
7) SUPPORT SECONDARY A/C CONDENSATE
8) NAIL STOP DRYER VENT