| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/11/2006 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 04/04/2006 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PER TRUSS CALC'S A02 2 POINT BEARING TRUSSES ALLOW 1/2" DEFLECTION GARAGE WALL & LIVING ROOM WALL 2) PER TRUSS CALC'S TRUSSES NOT PER PLAN 3) LOOSE SHEETS 4) ROOF PANELS MUST SPAN 3 TRUSSES OR 2 BAYS OR BLOCK & NAIL 24" ON CENTER |