Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM00284

Parcel: 113030650


Addresses:

3755 N TYNDALL AV


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM00284

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/02/2007 FRAMING Approved IVRS - Inspection :*
07/18/2006 FRAMING Partial Approval IVRS - Inspection :*
1) PENDING REVISION OR OMISSION GARAGE SERVICE DOOR
2) OK TO SHEETROCK
07/14/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
07/13/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE 4 GANG BOXES
2) MISSING BLOCK W/H PLENIUM
3) BLOCK TUB WALLS
4) CHECK ALL A/B LOOSE
5) REMOVE STAPLES AT HOMERUNS
6) SERVICE DOOR MISSING PER PLAN GARAGE
7) INSTALL DOOR OR OMIT FROM PLAN
07/12/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
06/15/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
06/14/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/07/2006 FRAMING Not ready for Inspection IVRS - Inspection :*