Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/05/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 07/03/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SMOKE DETECTORS NOT INTERCONNECTED 2) NEED HOUSE ADDRESS 3) HALL BATH GFCI WON'T TRIP |
|
| 06/27/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 06/19/2006 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) WORK NOT COMPLETE |
|
| 06/14/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SHARP POINT SCREWS REMOVED FROM DEAD FRONT MAIN SERVICE PANEL. 2. INSTALL B-VENT WATER HEATER 3. INSTALL HIGH VENT COMBUSTION RELIEF WATER HEATER CLOSET DOOR. 4. SECURE GAS LINE ROOFTOP UNIT INSTALL DRIP LEG APPLIANCE SIDE AGA VALVE 5. INSTALL CONDENSATE LINE ROOFTOP UNIT 6. CIRCUITS 5 & 7 MISSING KITCHEN 7. SMOKE DETECTORS MUST BE INTERCONNECTED |