Permit: T06CM00272

Parcel: 12701004C

Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Permit Number - T06CM00272

Inspection Description - PLUMBING - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
04/13/2006 PLUMBING - ABOVE CEILING Approved IVRS - Inspection :*
03/09/2006 PLUMBING - ABOVE CEILING Partial Approval IVRS - Inspection :*
1. HANGERS ARE REQUIRED WITHIN EIGHTEEN INCHES EACH SIDE OF A COUPLING, AT EACH CHANGE OF DIRECTION AND AT THE END OF BRANCHES.
2. OK TO COVER WALLS.
NOTE: PLUMBERS TAPE NOT APPROVED
CONNECTION BETWEEN N/H & ABS TO BE A MISSION COUP