Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/18/2007 | MECHANICAL - INTERMEDIATE | Approved | ||
| 12/06/2006 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE A NAIL PLATE AT CONDENSATE 2ND FLOOR. 2. PROVIDE A FILTER RACK FOR FINAL AIR INTAKE. 3. SUPPLY DUCT TO LAUNDRY ROOM STILL SMASHED. 4. PROVIDE A COLLAR THRU THE WALL TO CONNECT RANGE HOOD EXHAUST. 5. ADD ANOTHER PLATE STRAP @ DRYER VENT |
|
| 10/12/2006 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ADJUST KIT. HOOD NO DUCT OVER KITCHEN CEILING. CRIMPING A/C FLEX DUCT TO LAUNDRY RM. AT Y |
|
| 09/21/2006 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* DRYER VENT DOES NOT FIT IN WALL. DO NOT SMASH THE VENT PIPE TO MAKE IF FIT. YOU CAN USE 3X4 DOWNSPOUT IF NEEDED. INSULATE 2ND FLOOR SIDE WALL BOX & T-WYE. PROVIDE A SCREW OR CLAMP 1ST FLOOR EXHAUST FAN. PROVIDE A CONDENSATE DRAIN. |