Permit: T06CM00238

Parcel: 140322140

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T06CM00238

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/15/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
02/13/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*SEE PREVIOUS WRITE UP
02/06/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*SECURE GROUNDING ELECTRODE CONDUCTOR BETWEEN GROUND ( FINISH GRADE) & PANEL
INSTALL METAL ADDRESS TAG AS REQUIRED BY BOTH TEP 7 TEH INTERNATIONAL RESIDENTIAL CODE.
EXPOSED PVC TO BE SCH. 80 PLEASE INSTAL PVC -CUT PVC ST WE CAN SEE SCH. 80 STAMP ON CONDUIT AT INSTALLATION