Permit: T06CM00234

Parcel: 141092190

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM00234

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/22/2006 FRAMING Approved IVRS - Inspection :*
09/15/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL GARAGE KING STUDS AS PREVIOUSLY REQUESTED
2) REFEE WILL APPLY
3) INSTALL BANG PLATES WHERE PREVIOUSLY REQUESTED AND AT GARAGE S.E. CORNER
09/13/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DBL STUD UNDER DBL GIRDER IN GARAGE, NEEDS TO BE UNDER GIRDER
2) WIRE MESH NEEDS TO BE SECURED OVER PATIO PORCH
3) ELECTRIC OUTLET MISSING IN GARAGE ROOF
4) TIE STRAPS ENTRY DOOR TOP PLATE
5) PROTECTIVE COVERS AT TOP PLATES IN LIVING ROOM FOR ELECTRICAL WIRES BY SLIDING DOOR, ALSO IN DEN
6) GROUND METAL BOX IN MASTER BATH
7) MID-SPAN BLOCKING MASTER CLOSET NOT NAILED
8) AT GARAGE DOOR OPENING FLOOR PLAN CALLS FOR 4 X 4 POST 2/SD3 REFER TO SD2 NOTE #5