Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM00234

Parcel: 141092190

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM00234

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/18/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/08/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER PAUL
07/25/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 4/SD3 NOT COMPLIED WITH AT 2 X 12 BEAM
2) 4 X 12 BEAM WAYNED ON END BEARING ONLY 1 1/2" MUST BEAR 4"
3) 4 X 12 BEAM MUST BEAR ON DBL 2 X 4 POST. PRESENTLY POST IS CUT AND SPLICED
4) SHEARWALLS NOT NAILED
5) NO LADDER ACCESS TO ROOF
6) STOPPED INSPECTION