Permit: T06CM00227

Parcel: 133233580


Addresses:

7685 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM00227

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
06/03/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
05/28/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
UNABLE TO INSPECT CLOSET FLANGES W/TOILETS INSTALLED
05/15/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
SECURE CLOSET FLANGES TO FLOOR W/SCREWS
UPC IS #9 PG. 342 SEC 314.2
CORRECT PIPE SUPPORTS AS PREVIOUSLY REQUESTED
CONTINUED "DENIED" INSPECTIONS WILL RESULT IN REINSPECTION FEES
04/22/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SUPPORT AND SECURE OVERHEAD PIPING PROPERLY AND HAVE CLOSET FLANGE INSPECTION AFTER FLOORING IS INSTALLED AND BEFORE SETTING STOOLS
04/15/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OFFSET WATER LINE CAUSING STRAIN ON PVC
DF VENT
SUPPORT AND SECURE VENT W/PIPE SUPPORTS
SEAL JOINTS ON PIPE INSULATION
OK TO COVER WALLS AFTER
INSTALLING BACKING FOR MS FAUCET BRACKET AND LAVITORY
04/10/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
- TEST ON DWV THRU ROOF OK
- SUPPORT HORIZONTAL PIPING PER UPC T 3-2
- 60 PSI TEST ON WATER
- OK TO INSULATE
- HAMMER ARRESTOR REQUIRED AT FLUSH-O-METER
- 6" RWL AND OVERFLOW TEST OK IN BUILDING
- SUPPORT & SECURE CLOSET FLANGES