Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM00227
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/03/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
05/28/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* UNABLE TO INSPECT CLOSET FLANGES W/TOILETS INSTALLED |
|
05/15/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* SECURE CLOSET FLANGES TO FLOOR W/SCREWS UPC IS #9 PG. 342 SEC 314.2 CORRECT PIPE SUPPORTS AS PREVIOUSLY REQUESTED CONTINUED "DENIED" INSPECTIONS WILL RESULT IN REINSPECTION FEES |
|
04/22/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SUPPORT AND SECURE OVERHEAD PIPING PROPERLY AND HAVE CLOSET FLANGE INSPECTION AFTER FLOORING IS INSTALLED AND BEFORE SETTING STOOLS |
|
04/15/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OFFSET WATER LINE CAUSING STRAIN ON PVC DF VENT SUPPORT AND SECURE VENT W/PIPE SUPPORTS SEAL JOINTS ON PIPE INSULATION OK TO COVER WALLS AFTER INSTALLING BACKING FOR MS FAUCET BRACKET AND LAVITORY |
|
04/10/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - TEST ON DWV THRU ROOF OK - SUPPORT HORIZONTAL PIPING PER UPC T 3-2 - 60 PSI TEST ON WATER - OK TO INSULATE - HAMMER ARRESTOR REQUIRED AT FLUSH-O-METER - 6" RWL AND OVERFLOW TEST OK IN BUILDING - SUPPORT & SECURE CLOSET FLANGES |