Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/05/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 04/04/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* EAST HALF PIPE WRAPS & TRAP PRIMERS OK |
|
| 04/03/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* APPROVED PLAN ON SITE. WATER TEST INTERIOR BUILDING UNDERSLAB GREASE & DWV OK CALL FOR INSPECTION FOR PRE-SLAB |
|
| 03/21/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 3" GREASE WASTE UNDERGROUND WATER TEST OK 4" SANITARY BUILDING INTERIOR IS ALL NEW PIPING WATER TEST IS PARTIAL ITEM #17 ON P-1 IS PROP SINK AND REQUIRES INDIRECT DRAIN RECEPTOR, ITEM #19 DISHWASHER REQUIRING INDIRECT DRAIN, THERE ARE (3) HAND SINKS IN BAR AREA THAT REQUIRE DIRECT SANITARY CONNECTION. PLAN IS APPROVED IN ERROR. PROVIDE REVISED APPROVED PLAN. PROVIDE APPROVED HEALTH DEPT. PLAN DO NOT COVER AREAS LISTED ABOVE. |
|
| 03/17/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. ALL PIPING TO BE EXPOSED & PROPERLY SHADED WITH MINIMUM 1/4" PER FOOT FALL 2. INSTALL PER APPROVED PLAN OR PROVIDE REVISED APPROVED PLAN OF INSTALLATION. |