Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM00195
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/02/2006 | FRAMING | Approved | IVRS - Inspection :* | |
05/17/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. COMPLETE LATH 2. BANG PLATE TOP PLATE IN KIT 3. MECH. NOT PER PLAN. |
|
05/09/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TIGHTEN AB THROUGHOUT 2) PEX TO CLOSE TO B-VENT 3) BANG PLATES ON ELECTRIC 4) SHIM HDRS WHERE NEEDED 5) FIRE STOP SOFFIT 6) 1" CLEARANCE TO COMBUSTIBLES AROUND B-VENT 7) ATTIC SWITCH TO FAR FROM ACCESS OPENING 8) STOPPED INSPECTION-NOT READY |