Inspection History: PLUMBING - FINAL

Permit Number - T06CM00185

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/10/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
07/09/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
07/05/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
COMPLETE #1 FROM 6/28/07 ON ALL FLOOR SINKS
(ALL INDIRECT DRAINS TO HAVE MINIMUM 1" AIR GAP AT TERMINATION)
06/28/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ALL INDIRECT DRAINS TO HAVE MINIMUM 1" AIR GAP AT TERMINATION
2. DRAIN FROM ESPRESSO MACHINE SHALL BE GRAVITY AND BE RIGID CONNECTION TO PVC DRAIN
3. PVC SHALL BE PRIMED & THEN GLUED
4. PROVIDE LISTING FOR WATTS POLYETHENE TUBING USED AS WATER SUPPLIES.
5. LABEL EACH BACKFLOW DEVICE FOR ITS USE
6. COMPLETE SODA DISPENSER WATER SUPPLIES
06/21/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*