Permit: T06CM00175

Parcel: 140192180


Addresses:

890 E VUELTA SUAVE

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/08/2006 BUILDING - FINAL Approved
08/04/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH LIGHTING CODE-HAVE PLAN CHECKER APPROVED OUTSIDE LIGHTS AS IS
2) MOVE A/C DISCONNECT WEST 8" CANNOT BE OVER A/C UNIT
3) REPAIR STUCCO AT A/C REFRIDGERATION LINE
4) COMPLETE BULB INSTALLATION
5) KITCHEN GFCI NOT TRIPPING WHEN TESTED WEST WALL WITH SHEILD
07/26/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MARK A/C UNIT IN GARAGE MODEL # TO DETERMINE COMPACITY
2) POST HOUSE ADDRESS NUMBERS
3) CANNOT HAVE EXPOSED BULB CLOSETS
4) KITCHEN GFCI NOT TRIPPING WHEN TESTED WEST WALL
5) OVER 6" OVER HANG KITCHEN COUNTER TOP REMOVE RECEPTACLE
6) PAINT EXPOSED VENTS ON ROOF
7) MAX 30 FUSE A/C DISCONNECT
8) INSTALL POST TENSION TAG H20 SERVICE PIPING
9) A/C CONDENSATE TO BE TRAPPED AND VENTED
10) EXTERIOR GFCI RECEPTACLES NOT TRIPPING WHEN TESTED
11) A/C DISCONNECT CANNOT BE BEHIND UNIT
12) STOPPED INSPECTION