Permit: T06CM00157

Parcel: 140550870

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/23/2006 BUILDING - FINAL Approved IVRS - Inspection :*
08/21/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PROOF OF MECHANICAL INTERMEDIATE APPROVAL
2) PROVIDE TEP SEAL ON ELECTRIC PANEL HOT DEAD FRONT
3) ATTIC ACCESS BLOCKED BY DUCT WORK SEE PLAN
4) STAIR GUARD RAIL CANNOT HAVE GAPS LARGER THAN 4"
5) SEAL HOLES IN GARAGE WALLS
6) KITCHEN PENINSULA REQUIRES 1 GFCI OUTLET. CANNOT BE UNDER OVER HANG GREATER THAN 6"
7) GFCI OUTLET REQUIRED WITHIN 24" OF LEFT SIDE KITCHEN SINK