Inspection History: FRAMING

Date Description Inspector Results Comments
08/14/2006 FRAMING Approved IVRS - Inspection :*
08/02/2006 FRAMING Partial Approval IVRS - Inspection :*
- GET ENGINEERED REPAIR FOR FLOOR JOIST L/R
- OKAY TO INSULATE AND DRYWALL AREAS OTHER THAN FLOOR JOIST.
07/25/2006 FRAMING Cancelled CANCELLED PER SUPER
06/06/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OUTSIDE HOSE BIB REQUIRES ANTI-SIPHON VALVE
2) NO DWV WATER TEST
3) PLUMBING AND ELECTRIC OUT OF WALL POWER ROOM
4) NAIL PROTECT PLUMBING
5) COMPLETE WIRING HALL BATH
6) PROVIDE DRY WALL NAILER HALL BATH WINDOW
7) MECHANICAL MAKE UP AIR MUST BE 10 FEET FROM SEWER VENT
8) TRUSS WEB DAMAGED BY PLUMBING. LIVING ROOM NORTH EAST CORNER/WALL. PROVIDE ENGINEERS APPROVED REPAIR WITH CITY STAMP
9) HIP TRUSS NOT NAILED TO HANGER OVER ENTRY
10) NAIL SHEAR CHANNELS PER 5/DT1
11) INSULATE RETURN AIR PLENIUM R-5
12) STOPPED INSPECTION-TOO MANY ITEMS