Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM00106
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ITEMS 2 AND 5 OF 3/7/05 NOT DONE |
|
03/07/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWN MISSING SOUTH WEST CORNER-PROVIDE APPROVED ALTERNATE 2) 3 PT BEARING TRUSSES NOT BEARING AT MID POINT 3) ANCHOR BOLTS MISSING PORCH COLUMNS 4) CLIP KING STUDS TO BEAM AND REAR PORCH 5) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF PLATE SURFACE 6) STRAP NON OVERLAPPING DBL TOP PLATES |