Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM00104
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) A TIGHTEN CS 20 SIDE STRAPS 2) CLIP/NAIL GABLE PER 2/D2 |
|
05/25/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALLS NOT NAILED PER SCHEDULE 2) <3> OSB 2ND FLOOR S.E. CORNER MISSING 3) 2 ROWS CS20'S MISSING ABOVE AND BELOW FRONT WINDOW 1ST FLOOR (SEE DETAIL 1/5 AND COMPLY HORIZONTALLY AND 2ND FLOOR FRONT WINDOW ALSO 4) REPLACE METAL WIND BRACING SOUTH SIDE 5) NAIL METAL WIND BRACING 2 NAILS TOP AND BOTTOM AND ONE NAIL EACH STUD; RE-NAIL OVER PENETRATED METAL WIND BRACING 6) RE-NAIL EXTERIOR STRAPS ACROSS 1ST TO 2ND FLOOR EXCESSIVELY BUCKLED 7) NEED LADDER TO INSPECT ROOF 8) STOPPED INSPECTION-TOO MANY ITEMS UN-DONE 9) COMPLETE ALL AND RECALL |