Permit: T06CM00104

Parcel: 141094800

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/08/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/02/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) A TIGHTEN CS 20 SIDE STRAPS
2) CLIP/NAIL GABLE PER 2/D2
05/25/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEARWALLS NOT NAILED PER SCHEDULE
2) <3> OSB 2ND FLOOR S.E. CORNER MISSING
3) 2 ROWS CS20'S MISSING ABOVE AND BELOW FRONT WINDOW 1ST FLOOR (SEE DETAIL 1/5 AND COMPLY HORIZONTALLY AND 2ND FLOOR FRONT WINDOW ALSO
4) REPLACE METAL WIND BRACING SOUTH SIDE
5) NAIL METAL WIND BRACING 2 NAILS TOP AND BOTTOM AND ONE NAIL EACH STUD; RE-NAIL OVER PENETRATED METAL WIND BRACING
6) RE-NAIL EXTERIOR STRAPS ACROSS 1ST TO 2ND FLOOR EXCESSIVELY BUCKLED
7) NEED LADDER TO INSPECT ROOF
8) STOPPED INSPECTION-TOO MANY ITEMS UN-DONE
9) COMPLETE ALL AND RECALL