Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* UNDERGROUND AND INTERMEDIATE DWV W/VTR TO UNISEX RESTROOM OK WATER PIPING AT RESTROOM - OK PLAN STILL SHOWS TWO RESTROOMS. REVISE PLAN TO SHOW INSTALLATION. REVISE GAS PIPING & WH PLAN OR INSTALL. CALL FOR CLOSET FLANGE INSPECTION (PROGRESS) |
|
| 05/30/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PIPING WAS REPLACED BY SOMEONE THAT DOES NOT HAVE KNOWLEDGE OF PLUMBING INSTALLATIONS. 1. FURNCO COUPLINGS ARE NOT ALLOWED WITHIN A BUILDING 2. PROPER WYE PATTER DRAINAGE FITTINGS ARE REQUIRED. 3. WC SHALL BE PROPERLY VENTED 4. V&R SHALL BE A MIN. OF 7 SQ. INCHES. 5. UPPER TERMINAL REQUIRES A CLEAN OUT DOLLAR PLUGS ARE OK TO PLUG OLD FIXTURES GEM CAP IS NOT A PERM CAP 6. PERM CAP REQUIRED. |
|
| 05/22/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* YOUR REVISED PLAN IS OK, BUT I NEED TO SEE A PLAN OF THE EXISTING PLUMBING IN THIS BUILDING. I BELIEVE THAT PIPING BELOW FLOOR MAY HAVE BEEN INSTALLED PREVIOUSLY W/OUT PERMITS. ALSO THERE ARE FLOOR SINKS THAT REQUIRE PERMANENT CAPS. ALL NEW WORK DONE MUST BE INSPECTED. 1. PROVIDE PLAN OF EXISTING BUILDING. 2. UNCOVER ALL WORK THAT IS NOT REFLECTED ON EXISTING PLAN |
|
| 05/04/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* - WORK HAS TO LOOK LIKE PLAN. - INSTALL PER PLAN. - YOU MAY WISH TO GET YOUR PLAN REVISED - IF THE PLAN DOES NOT REFLECT YOUR WISHES, BUT THE PLANS EXAMINER MAY REQUIRE CERTAIN THINGS TO BE INSTALLED TO MEET BUILDING CODE REQUIREMENTS. - PIPING INSTALLED WITHOUT PERMITS. - WILL BE CAPPED AND OR ELIMINATED. |
|
| 05/01/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* WORK HAS NOT BEEN DONE ACCORDING TO PLAN. ALL NEW WORK REQUIRES A TEST. EXISTING FIXTURES TO BE DELETED REQUIRE PERM. CAPS. BROKEN VENT AT WC NEEDS TO BE CORRECTED. CALL FOR INSPECTION WHEN READY. |
|
| 04/27/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 03035 - 03036 - 03075 NOT READY NO ONE ON SITE - PROVIDE ACCESS |