Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T06CM00092
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/05/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
09/19/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. MICRO HOOD IS MOUNTED TO CLOSE TO RANGE -- SEE INSTALLATION MANUAL NEC 110.3 2. PANEL DIRECTORY IS INCORRECTLY IDENTIFIED - NEC 408.4 3. MAXIMUM 4' CORD ON DISHWASHER - NEC 422.16 B2 4. IDENTIFY WHITE CONDUCTOR USED AS HOT @ DISCONNECTS -- NEC 310.12 5. AC DISCONNECT OVER FUSED, AND IDENTIFY IF HEATER KIT IS INSTALLED. 6. NEED ROOFTOP SERVICE RECEPTACLE FOR EACH UNIT UNLESS SUPPLIED BY "HOUSE" PANEL -- 210.63 7. INSPECTION/PERMIT IS FOR UNIT ONE ONLY REVISE PERMIT TO SHOW UNIT #1 AND #2 FOR THIS ADDRESS. 8. NEED PROPER CONNECTOR FOR DISHWASHER CORD -- NEC 400 |