Permit: T06CM00049

Parcel: 141092300


Addresses:

6560 E SPLENDID LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM00049

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/16/2006 FRAMING Approved IVRS - Inspection :*
06/14/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 3PT BEARING TRUSSES NOT BEARING AT MID-POINT.
2. SD2 TRUSS NEEDS MIDPOINT HANGER
3. CUT DOUBLE TOP PLATE AT RANGE HOOD REQUIRES FHA STRAPS WITH 6-16D NAILS EACH END, EACH SIDE.
4. HOLD DOWN MISSING NAILS AND NUTS.
5. STOPPED INSPECTION TOO MANY ITEMS.