Permit: T06CM00012

Parcel: 119044280


Addresses:

3555 S 8TH AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/15/2006 FRAMING Approved IVRS - Inspection :*
05/03/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) PENDING APPROVED PLAN
2) DWV TEST APPROVED
05/01/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. STRUTS LEDGER MISSING REAR OVERHANG PER APPROVED DETAIL.
2. MASTER BEDROOM #1 & #2 BATH ELECT. FRAME PLB NOT ON PLAN.
3. LAUNDRY STORAGE FRAME, ELECT. ETC NOT ON PLAN.
4. NEED H20 TEST D.W.V THROUGH ROOF
5. INSTALL H25'S INTERIOR BEARING PLATE TO STUD TO PLATE
6. INSTALL FIRE BLOCKS ALL DROPPED CEILING AREAS.
7. INSTALL H25'S RAFTERS AT BEARING.
8. INSTAL A35'S LEDGER TO STUDS.
9. FRONT PORCH NOT ON PLOT PLAN.
10. STRAP HEADERS AT BEARING.
11. H20 HEATER ROOM NOT ON PLANS.
12. NEED POSITIVE CONNECTION FRONT PORCH LEDGERS TO STUDS BEHIND.
13. STUDS EMBEDDED IN CONCRETE TO BE PRESSURE TREATED OVER WOOD OR CUT OFF & INSTALL TREATED BOTTOM PLATE.
14. STOPPED INSPECTION