Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/03/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) PENDING APPROVED PLAN 2) DWV TEST APPROVED |
|
| 05/01/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. STRUTS LEDGER MISSING REAR OVERHANG PER APPROVED DETAIL. 2. MASTER BEDROOM #1 & #2 BATH ELECT. FRAME PLB NOT ON PLAN. 3. LAUNDRY STORAGE FRAME, ELECT. ETC NOT ON PLAN. 4. NEED H20 TEST D.W.V THROUGH ROOF 5. INSTALL H25'S INTERIOR BEARING PLATE TO STUD TO PLATE 6. INSTALL FIRE BLOCKS ALL DROPPED CEILING AREAS. 7. INSTALL H25'S RAFTERS AT BEARING. 8. INSTAL A35'S LEDGER TO STUDS. 9. FRONT PORCH NOT ON PLOT PLAN. 10. STRAP HEADERS AT BEARING. 11. H20 HEATER ROOM NOT ON PLANS. 12. NEED POSITIVE CONNECTION FRONT PORCH LEDGERS TO STUDS BEHIND. 13. STUDS EMBEDDED IN CONCRETE TO BE PRESSURE TREATED OVER WOOD OR CUT OFF & INSTALL TREATED BOTTOM PLATE. 14. STOPPED INSPECTION |