702 W IRVINGTON RD

Inspection Status: Continued

Inspection History: GRADING - FINAL

Date Description Inspector Results Comments
03/17/2011 GRADING - FINAL Continued
03/16/2011 GRADING - FINAL Continued NO ONE WORKING ON SITE AT THIS TIME.
10/31/2007 GRADING - FINAL Not Applicable Spoke to Super in regards to extruded curb line. If contractor installs extruded curb 2.5' from face of sidewalk, wheel stops will not need to be installed.
10/11/2007 GRADING - FINAL Partial Approval Met with contractor on site went over changes to scuppers and sidewalks. Contractor raised scupper inlet.
10/03/2007 GRADING - FINAL Correction Required Met with Duane site super. looked over scupper installation. Contractor needs to install scuppers with 6" opening for inlet. Per Standard Detail 205.
08/08/2007 GRADING - FINAL Correction Required Contractor forming up scuppers, contractor has not provided approved revised drawings.
06/13/2007 GRADING - FINAL Correction Required Met on site with Hector (super) and Hillary (engineer) Discussed changes to approved drawings. I explained to Hillary and Hector that all changes to the drawings need to need to be approved by WillDan before final inspections.
05/22/2007 GRADING - FINAL Correction Required Met with David on site went over changes to approved drawings. No one has contacted Willdan yet for approval to changes.
05/17/2007 GRADING - FINAL Correction Required Contractor installed construction entrance. Contractor still needs to address correction notice issued on 4/23/07.
04/23/2007 GRADING - FINAL Correction Required Met on site with Hector site super. Issued Correction Notice. Contractor needs to:
1- Clean all track out from site.
2- Clean all concrete wash out.
3- Install sidewalk scuppers, per approved plans.
4- Sidewalk not installed per DS.
5- Call in per con meeting.
6- Contractor needs to provide approved grading plan.
7- Provide scupper detail from engineer.
8- Have engineer provide crossection of north side of project (sidewalk).
Non-compliance will result in a Stop Work Order.
04/20/2007 GRADING - FINAL Correction Required Contractor needs to sweep up track out. Clean up concrete wash out. Set up meeting with contractor for 0900, 4/23/07. Contractor placed concrete sidewalk on north side of project at wrong elev. and did not install scuppers.