Permit: T06BU02701

Parcel: 116041060

Inspection Status: Approved

Inspection History: POOL/SPA HEATER

Date Description Inspector Results Comments
05/23/2007 POOL/SPA HEATER Approved IVRS - Inspection :*
05/22/2007 POOL/SPA HEATER Partial Approval IVRS - Inspection :*
05/16/2007 POOL/SPA HEATER Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR HAD QUESTIONS
05/04/2007 POOL/SPA HEATER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HEATER PTR LOOSE
2) MUST BAR THREADS ON PTR TERMINATION
3) METAL FENCE HEIGHT TO BE MINIMUM 5' HIGH MEASURED FROM OUTSIDE ENCLOSURE
4) GATES TO OPEN OUT AWAY FROM POOL
5) GATES TO BE SELF CLOSING LATCHING
6) CANNOT HAVE CLIMABLE OBJECTS OUTSIDE OF ENCLOSURE WITHIN 5' RADIUS OF TOP OF ENCLOSURE
7) SOUTH BLOCK WALL NOT 5' HIGH
8) SVRS #022937
9) STOPPED INSPECTION
04/17/2007 POOL/SPA HEATER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL SVRS
2) PERIMETER ENCLOSURE TO BE MINIMUM 5' HIGH MEASUREMENT FROM OUTSIDE ENCLOSURE. CANNOT HAVE ANY CLIMABLE OBJECTS WITHIN 5' RADIUS OF TOP OF WALL
3) LOOSE DIRT NOT ALLOWABLE UNDER METAL FENCE, MUST HAVE PERANENT NON-MOVEABLE SUBSTANCE
4) INSTALL POOL HEATER PRESSURE-TEMP RELIEF VALVE AND LINE
5) STOPPED INSPECTION