Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA HEATER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/23/2007 | POOL/SPA HEATER | Approved | IVRS - Inspection :* | |
| 05/22/2007 | POOL/SPA HEATER | Partial Approval | IVRS - Inspection :* | |
| 05/16/2007 | POOL/SPA HEATER | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR HAD QUESTIONS |
|
| 05/04/2007 | POOL/SPA HEATER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HEATER PTR LOOSE 2) MUST BAR THREADS ON PTR TERMINATION 3) METAL FENCE HEIGHT TO BE MINIMUM 5' HIGH MEASURED FROM OUTSIDE ENCLOSURE 4) GATES TO OPEN OUT AWAY FROM POOL 5) GATES TO BE SELF CLOSING LATCHING 6) CANNOT HAVE CLIMABLE OBJECTS OUTSIDE OF ENCLOSURE WITHIN 5' RADIUS OF TOP OF ENCLOSURE 7) SOUTH BLOCK WALL NOT 5' HIGH 8) SVRS #022937 9) STOPPED INSPECTION |
|
| 04/17/2007 | POOL/SPA HEATER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL SVRS 2) PERIMETER ENCLOSURE TO BE MINIMUM 5' HIGH MEASUREMENT FROM OUTSIDE ENCLOSURE. CANNOT HAVE ANY CLIMABLE OBJECTS WITHIN 5' RADIUS OF TOP OF WALL 3) LOOSE DIRT NOT ALLOWABLE UNDER METAL FENCE, MUST HAVE PERANENT NON-MOVEABLE SUBSTANCE 4) INSTALL POOL HEATER PRESSURE-TEMP RELIEF VALVE AND LINE 5) STOPPED INSPECTION |