Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06BU02434

Parcel: 125115270


Addresses:

3615 E 3RD ST


Inspection Status: Approved

Inspection History: POOL/SPA ELECTRIC

Permit Number - T06BU02434

Inspection Description - POOL/SPA ELECTRIC

Inspection Status - Approved

Date Description Inspector Results Comments
10/15/2007 POOL/SPA ELECTRIC Approved IVRS - Inspection :*
09/21/2007 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
DO NOT CALL FOR POOL ELECTRICAL BEFORE COMPLETE, WATER IN POOL AND FULLY OPERATIONAL
AND EQUIPMENT GROUND IS REQUIRED TO BE RAN WITH POOL FEEDER -- SEE NEC 680.25B

GROUND RODS STILL NOT 6' APART
09/19/2007 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUND RODS TO BE MINIMUM 6' APART
2) NEED AN EQUIPMENT GROUND RAN TO POOL SUB-PANEL WITH FEEDERS
09/18/2007 POOL/SPA ELECTRIC Cancelled CANCELLED PER VALERIE OF CIMARRON CIRCLE CONST. #881-2777
09/18/2007 POOL/SPA ELECTRIC Not ready for Inspection IVRS - Inspection :*
09/17/2007 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
OK LIGHT IN POOL - POTTING COMPOUND

1. PANELS & EQUIPMENT NOT READY
01/04/2007 POOL/SPA ELECTRIC Not ready for Inspection IVRS - Inspection :*
INSPECTION MADE 1/3/07
01/03/2007 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
OK TO POUR DECK
OK BONDING TO JIGS FOR 3 GRAB RAILS AND HANDICAP RAMP
01/02/2007 POOL/SPA ELECTRIC Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. POST ADDRESS FOR JOBSITE @ STREET
2. JIG FOR HANDICAP RAMP NOT BONDED
12/06/2006 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
OK TO GUNITE
1. PLEASE RECALL FOR COOL DECK INSPECTION TO CHECK BONDING TO METAL.