Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/12/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/09/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. AT UNDERGROUND TANK -- ALL WIRING METHODS AND BOXES/FITTINGS TO BE APPROVED FOR CLASS 1 DIVISION 1 LOCATIONS - NEC 501.4 A1, A3 - UNDERGROUND PIT AREA IS CLASS 1 DIVISION 1 AREA PER NEC 514.3 B1
ALSO, WIRING METHOD AT DISPENSER (L.B) TO MEET THE CLASS 1 TO DIVISION 1 REQUIREMENT
2. EMERGENCY STOP TO DISCONNECT ALL VOLTAGES TO DISPENSER NEC 514.11, 514.13 - PROVIDE VERFICATION AND LETTER OF COMPLIANCE.
03/08/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
03/07/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
OK PACKING @ 1. TANK LOCATION (2)
2. DISPENSER LOCATION (2)
3. PARTS GUTTER (3)