Permit: T06BU01852

Parcel: 141283860

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
12/11/2006 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
11/30/2006 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SVRS S/N 016783
2) YOU NEED A JUMPER WIRE AROUND THE NORTH ? PORCH FOR THE FENCE NORTH OF THE GATE TO BE PROPERLY BONDED
2) POOL SHOULD NOT BE FILLED BEFORE ALL FINALS ARE COMPLETE
11/16/2006 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
1. YOU MAY NOT HAVE A VALVE BETWEEN SVRS AND PUMP
2. HAVE ANTI-VORTEX COVERS @ SITE
3. BURY YOUR CONDUIT 12" OR COVER (LIQUID LIGHT) WITH CONCRETE
09/12/2006 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection :*