Permit: T06BU01755

Parcel: 117091290


Addresses:

1116 S 7TH AV

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
05/01/2007 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
1) NO SVRS REQUIRED
04/18/2007 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) IF USING EAST GATE AND WALL AS ENCLOSURE ALL WINDOWS MUST BE SECURED SHUT SO AS THEY CANNOT BE OPENED MORE THAN 4"
2) IF USING WEST GATE AND WALL GATE SHOUD OPEN OUTWARD AWAY FROM POOL AREA
3) SCREWS INTO CANE BOLT AT REAR GATTE CAN BE REMOVED MUST HAVE PERMANENT ATTACHMENT SUCH AS WELDING
4) HAVE PLUMBING PLAN STAMPED AND SIGNED BY CITY PLAN CHECK REGARDING "NO SVRS" REQUIRED PLEASE HAVE THAT NOTED ON PLANS
03/20/2007 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL SVRS
2) GATES TO OPEN OUT AWAY FROM POOL
3) CHAIN LINK FENCE OUTSIDE OF BLOCK WALL IS CLIMABLE-NOT ALLOWED
4) DBL GATE IN REAR-ONE SIDE NEEDS TO BE PERMANENTLY SECURED SHUT-OK TO WELD ? BOLT TO BRACKET ON FIXED SECTION OF GATE
5) PERIMETER WALL TO BE MAXIMUM 5' HIGH MEASURING FROM OUTSIDE OF ENCLOSURE
6) GATES TO BE SELF CLOSING-SELF LATCHING
7) STOPPED INSPECTION-INCOMPLETE