Permit: T06BU01102

Parcel: 106024960


Addresses:

3766 N PASTIME PL

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/12/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/22/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL EXTERIOR SHEATHING 6" SPACING
2) CANNOT USE SCREWS IN HURRICANE TIES OR JOIST HANGERS
3) HOLDOWNS REQUIRE DBL STUDS
4) NEED CORRECT HEADERS FOR BEARING
5) WILL NEED H2.5 HURRICANE TIE TOP PLATE TO STUD-OSB NON CONTINOUS PLAN CALLS FOR 2 X 4 AT 16" CENTERS WALLS
6) PLAN CALLS FOR 2 X VENTED BLOCKS BETWEEN RAFTERS AT BEARING
7) INSTALL PLATE BOLTS WITHIN 12" EACH END BOTTOM PLATES EXTERIOR
8) COMPLETE ALL PER APPROVED PLAN AND RECALL
9) STOPPED INSPECTION