Permit: T06BU01018

Parcel: 140420470


Addresses:

2425 E MEDINA RD


Inspection Status: Approved

Inspection History: GRADING - FINAL

Permit Number - T06BU01018

Inspection Description - GRADING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/17/2010 GRADING - FINAL Approved Approved
01/25/2007 GRADING - FINAL Partial Approval Contractor completed punch list and stabilized all areas. Contractor still cleaning up material from site.
01/18/2007 GRADING - FINAL Not ready for Inspection Met with site super. Looked at scupper installation.
01/16/2007 GRADING - FINAL Denied Complete punch list items #2, 3, 7, 8, 10, 12, 13, 14, 15, 18, 19 and 21.
12/12/2006 GRADING - FINAL Partial Approval Contractor continues to work on punch list.
12/08/2006 GRADING - FINAL Not ready for Inspection Punch List
1- Complete all fence and gate work.
2- Stabilize all areas distrubed by construction.
3- Complete all basin work. (Details A, B, C and D)
4- Complete all striping work.
5- Install wheel stops for HC parking.
6- Paint and strip bollards.
7- Install wheel stops parking area east and north sides.
8- Complete all grading around perimeter fence.
9- Repair down spouts.
10- Clean up construction debris.
11- Repair lip on HC ramp southwest corner of building.
12- Replace all broken curb.
13- Provide letter from engineer, per development standards and notes 44, 45 sheet 3.
14- Repair all holes in asphalt.
15- Remove trash dumpster and port-a-potty.
16- Complete all EX. curb work, south side of parking area.
17- Install trucated domes. (HC parking area)
18- Address parking southeast corner of parking lot.
19- Address detail 2/2 on sheet 3.
20- install handrail front of building.
21- Address ponding southeast corner of building next to HC parking.
11/08/2006 GRADING - FINAL Not ready for Inspection Spoke to site super in regards to HC installation needing trucated domes and scupper location. Contractor missed some scuppers.
10/31/2006 GRADING - FINAL Partial Approval Met on site with Brain site super to discuss scupper installation and location. Also requirements for concrete wash.