Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA GAS
Permit Number - T06BU00987
Inspection Description - POOL/SPA GAS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/23/2007 | POOL/SPA GAS | Approved | IVRS - Inspection :* | |
05/16/2007 | POOL/SPA GAS | Partial Approval | IVRS - Inspection :* PRESSURE TEST FROM METER LOCATION TO VALVE AT BBQ LOCATION & POOL HEATER OK 1. COMPLY WITH NOTE #2 FROM 08040 INSPECTION DATED 4/30/07 -- FAILURE TO COMPLETE WORK AT REINSPECTION WILL RESULT IN REFEE. |
|
04/30/2007 | POOL/SPA GAS | Not ready for Inspection | IVRS - Inspection :* 1. COMPLETE ALL PIPING AND TEST UP TO SYSTEM SUPPLY VALVE AND APPLIANCE SUPPLY VALVES. 2. PROVIDE PRESSURE RELIEF DEVICE LISTED FOR BTU DEMAND OF POOL HEATER. |
|
03/21/2007 | POOL/SPA GAS | Partial Approval | IVRS - Inspection :* 15 PSI TEST FROM METER LOCATION TO BBQ AND POOL EQUIP. AREA OK 1. SHALL SEE FINAL CONNECTIONS. |
|
03/20/2007 | POOL/SPA GAS | Denied | IVRS - Inspection : See detailed listing on site.| 999* TEST GAUGE IS DEFECTIVE, MATERIAL TYPE NOT PER PLAN AND NOT EXPOSED IN ENTIRETY. SEE 2003 UPC PE GAS YARD PIPING INSTALLATION STANDARD IAPMOIS 12-93 PAGE 349 & 352 |
|
03/19/2007 | POOL/SPA GAS | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
02/21/2007 | POOL/SPA GAS | Not ready for Inspection | IVRS - Inspection :* | |
02/16/2007 | POOL/SPA GAS | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO POOL PIPING APPROVED PLAN ON SITE ALL PIPING TO BE UNCOVERED FOR INSPECTIONS, TO PROVIDE PROOF OF CORRECT SIZING, BURIAL DEPTH, TRACER WIRE REQUIREMENTS, CORRECT MATERIAL TYPES, CORRECT BACKFLOW FOR POOL FILL REQUIRED, HOSE BIBS ON WATER SYSTEM THAT IS ENERGIZED REQUIRE VACUUM BREAKER NOW. FAILURE TO COMPLY SHALL RESULT IN REFEE. PROVIDE FULL TEST PRESSURE. HAVE CONTRACTOR ON SITE FOR NEXT INSPECTION. |
|
02/07/2007 | POOL/SPA GAS | Not ready for Inspection | IVRS - Inspection :* 1) THERE IS NO PLAN/PERMIT AT THE MAIL BOX 2) GAS, POOL AND WATER PIPING STILL COVERED |
|
02/06/2007 | POOL/SPA GAS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLAN/PERMIT 2) GAS COVERED WITHOUT INSPECTION 3) PROVIDE INSPECTION HISTORY FOR WATER PIPING TO POOL 4) POOL/SPA EQUIPMENT PIPING |