Permit: T06BU00987

Parcel: 105123390


Addresses:

4133 N STONE AV


Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Permit Number - T06BU00987

Inspection Description - POOL/SPA PLUMBING

Inspection Status - Approved

Date Description Inspector Results Comments
05/23/2007 POOL/SPA PLUMBING Approved IVRS - Inspection :*
RECEIVED (1) BACKFLOW CERTIFICATION
05/22/2007 POOL/SPA PLUMBING Not ready for Inspection IVRS - Inspection :
PROVIDE CORRECT SIGNAGE AS REQUESTED FROM PAST INSPECTION. CALL IN 08030 & 08040 FOR GAS CLEARANCE CARD. PAY REFEE PRIOR TO CALL IN TO COMPLETE THIS PROJECT.
05/21/2007 POOL/SPA PLUMBING Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTE #2 FROM 4/30/07 INSPECTION -
THIS INSPECTION SHEET.

CONCERNING PRESSURE RELIEF DEVICE. 08040 COMPLETE ALL WORK FROM ALL PAST NOTES. CALL IN ALL INSPECTIONS TO FINAL THIS PROJECT.

SEE NOTE #1 FROM 5/16/07 08040 PAY REINSPECTION FEE NO FINAL INSPECTION UNTIL FEE IS PAID.
05/16/2007 POOL/SPA PLUMBING Denied IVRS - Inspection :
See detailed listing on site.| 999*
COMPLETE ALL SPA PIPING AS REQUESTED ON 4/30/07 INSPECTION.
1. ALL HOSE BIBS SHALL HAVE TAMPER SCREW BROKEN OFF
2. HOSE BIB IN PUMP YARD SHALL REQUIRE PERMANENT SIGNAGE NON-POTABLE WATER DANGER DO NOT DRINK
(3) BACKFLOW CERTIFICATIONS ARE REQUIRED FOR POOL FILL BACKFLOW DEVICE
04/30/2007 POOL/SPA PLUMBING Not ready for Inspection IVRS - Inspection :*
COMPLETE INTERIOR POOL DEVICES PRIOR TO PLASTER
1. ALL HOSE BIBS REQUIRE VACUUM BREAKERS
2. COMPLETE ALL PIPING AND HAVE SYSTEM FUNCTIONAL
03/21/2007 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*
POOL PIPING WATER TESTED OK
1. SHALL SEE PIPE WRAPS PRIOR TO CONCRETE POUR IN EQUIPMENT AREA.
03/20/2007 POOL/SPA PLUMBING Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO INSPECTION WITHOUT PAYING REFEE FOR 3/19/07 INSPECTION
03/19/2007 POOL/SPA PLUMBING Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO CHANGE FOR LAST INSPECTION
EXPOSE ALL WORK
CONTRACTOR TO PAY REINSPECTION FEE
02/21/2007 POOL/SPA PLUMBING Not ready for Inspection IVRS - Inspection :*
PARNELL ON SITE: THIS IS A COMMERCIAL POOL. TEST PRESSURE TO BE PLACE. APPROVED PIPING PLAN OF THIS INSTALLATION TO BE ON SITE. ALL GAS PIPING & POOL PIPING TO BE EXPOSED AT REINSPECTION VACUUM BREAKERS TO BE IN PLACE ON HOSE BIB AT TIE IN FOR WATER SUPPLY & CORRECT BACKFLOW PROTECTION SHALL BE REQUIRED. SHALL PROVIDE REVISED CITY APPROVED GAS ISOMETRIC PLAN FOR ADDITION OF BBQ.
02/16/2007 POOL/SPA PLUMBING Denied IVRS - Inspection :
See detailed listing on site.| 999*