Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - FINAL
Permit Number - T06BU00766
Inspection Description - GRADING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2008 | GRADING - FINAL | Approved | ||
| 05/13/2008 | GRADING - FINAL | Partial Approval | PROVIDE AS-BUILT DRAWING SHOWING CHANGES MADE TO ORIGINAL GRADING PLAN. | |
| 05/07/2008 | GRADING - FINAL | Correction Required | 1) CLEAN UP CONSTRUCTION DEBRIS/MATERIAL IN ADJACENT LOT. 2) PROVIDE A CERT. STATEMENT FRON THE ENG. OF RECORD STATING THAT SITE WORK WAS COMPLETED IN ACCORDANCE WITH THE APPROVED PLANS. 3) PROVIDE AS-BUILT DRAWINGS. 4) INSTALL BIKE PARKING 5) SIDEWALK CROSS SLOPES >2% ON 3.5' SIDEWALKS ALONG EAST SIDE OF REAR BLDGS AND AT SOUTH PED ACCESS FROM RIGHT-OF-WAY. 6) INSTALL TRASH ENCLOSURE GATES. |
|
| 04/17/2008 | GRADING - FINAL | Not ready for Inspection | PROVIDE A CERTIFICATION FROM THE ENGINEER OF RECORD 1) STATING THAT THE DRAINAGE WAYS AND RET/DET BASINS WERE SUBSTANTIALLY COMPLETED PER THE APPROVED GRADING PLANS. 2) PROVIDE AN AS-BUILT DRAWING OF THE PROJECT. 3) THE CROSS SLOPE OF THREE SIDEWALK PANELS LOCATED ALONG THE SE CORNER OF THE SITE ARE GREATER THAN 2%. THE CONTRACTOR STATED THAT IN ORDER TO ACHIEVE THE 1:12 (8.3%) RUN SLOPE REQUIRED FOR PEDESTRIAN ACCESS ON THE SIDEWALK, IT IN TURN CAUSED A SMALL SECTION OF SIDEWALK TO HAVE A CROSS SLOPE GREATER THAN 2%. |