Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T06BU00766

Parcel: 115170980


Addresses:

1719 N HUACHUCA AV

Inspection Status: Approved

Inspection History: GRADING - FINAL

Date Description Inspector Results Comments
05/15/2008 GRADING - FINAL Approved
05/13/2008 GRADING - FINAL Partial Approval PROVIDE AS-BUILT DRAWING SHOWING CHANGES MADE TO ORIGINAL GRADING PLAN.
05/07/2008 GRADING - FINAL Correction Required 1) CLEAN UP CONSTRUCTION DEBRIS/MATERIAL IN ADJACENT LOT.
2) PROVIDE A CERT. STATEMENT FRON THE ENG. OF RECORD STATING THAT SITE WORK WAS COMPLETED IN ACCORDANCE WITH THE APPROVED PLANS.
3) PROVIDE AS-BUILT DRAWINGS.
4) INSTALL BIKE PARKING
5) SIDEWALK CROSS SLOPES >2% ON 3.5' SIDEWALKS ALONG EAST SIDE OF REAR BLDGS AND AT SOUTH PED ACCESS FROM RIGHT-OF-WAY.
6) INSTALL TRASH ENCLOSURE GATES.
04/17/2008 GRADING - FINAL Not ready for Inspection PROVIDE A CERTIFICATION FROM THE ENGINEER OF RECORD 1) STATING THAT THE DRAINAGE WAYS AND RET/DET BASINS WERE SUBSTANTIALLY COMPLETED PER THE APPROVED GRADING PLANS.
2) PROVIDE AN AS-BUILT DRAWING OF THE PROJECT.
3) THE CROSS SLOPE OF THREE SIDEWALK PANELS LOCATED ALONG THE SE CORNER OF THE SITE ARE GREATER THAN 2%. THE CONTRACTOR STATED THAT IN ORDER TO ACHIEVE THE 1:12 (8.3%) RUN SLOPE REQUIRED FOR PEDESTRIAN ACCESS ON THE SIDEWALK, IT IN TURN CAUSED A SMALL SECTION OF SIDEWALK TO HAVE A CROSS SLOPE GREATER THAN 2%.