Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - INTERMEDIATE
Permit Number - T06BU00766
Inspection Description - GRADING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/07/2008 | GRADING - INTERMEDIATE | Approved | ||
| 03/21/2008 | GRADING - INTERMEDIATE | Correction Required | CONTACTED SUPERITENDENT ABOUT CHANGES MADE TO SIDEWALK AND PED ACCESS | |
| 03/20/2008 | GRADING - INTERMEDIATE | Correction Required | CHANGE IN CONFIGURATION FROM APPROVED PLAN FOR SIDE WALK AND CROSSING ALONG BOTH SIDES OF ACCESS ROAD. PLAN SHOWS A SMALL 6' CONCRETE ISLAND AT SIDEWALK CROSSINGS. CONTRACTOR PROPOSED REMOVING THE ISLANDS AND REPLACING THEM WITH A VERTICAL CURB ALONG THE PARKING SIDE. |
|
| 02/27/2008 | GRADING - INTERMEDIATE | Correction Required | SITE WORK NOT COMPLETED, UTILITIES BEING INSTALLED. ANY CHANGES MADE TO THE GRADING PLAN MUST BE RE-APPROVED BY THE ENGINEER OF RECORD AND THE CITY OF TUCSON. |
|
| 10/05/2007 | GRADING - INTERMEDIATE | Correction Required | NO SITE WORK HAS BEEN STARTED, HOWEVER STRUCTURES ARE BEING BUILT. CONCRETE IN RET/DET BASINS, SLOPES NOT PER PLAN. PERIMETER WALL NOT IN PLACE. |
|
| 05/02/2007 | GRADING - INTERMEDIATE | Violation | NO ACTIVITY ON SITE, REVISED PLAN APPROVED; HOWEVER A GRADING PERMIT HAS NOT BEEN ISSUED - STILL UNDER A STOP WORK ORDER. | |
| 04/10/2007 | GRADING - INTERMEDIATE | Violation | SITE IS UNDER A STOP WORK ORDER. SITE DOES NOT HAVE AN ACTIVE APPROVED GRADING PERMIT AT THIS TIME. NO WORK BEING DONE AT THIS TIME. | |
| 03/22/2007 | GRADING - INTERMEDIATE | Violation | MET WITH CONTRACTOR, ENGINEER, DEVELOPER, AND THE CITY OF TUCSON TO DISCUSS OBTAINING A GRADING PERMIT PRIOR TO CONTINUING WORK AT SITE. | |
| 03/20/2007 | GRADING - INTERMEDIATE | Violation | STOP WORK ORDER ISSUED 3/15/07 - GRADING WITHOUT AN ACTIVE GRADING PERMIT. ALSO NEED SWPPP FOR PROJECT. CALL FOR RE-INSPECTION. CHECKED ON STOP WORK ON MONDAY 3/19/07 - NO ACTIVITY ON SITE. | |
| 03/15/2007 | GRADING - INTERMEDIATE | Correction Required | DOES SITE REQUIRE A SWPPP? NO GRADING PERMIT HAS BEEN ISSUED? WORK HAS STARTED, NO INSPECTIONS HAVE BEEN DONE. 1) MAINTAIN EXISTING SILT FENCE. 2) SWEEP UP TRACKED MATERIAL OFF OF PUBLIC ROADWAY. 3) MAINTAIN SLOPE LOCATED ALONG THE WEST SIDE OF SITE. SLOPE IS NOT STABILIZED AND NO SEDIEMNT CONTROLS ARE IN PLACE. GRADING PLAN IS INSUFFICIENT, CAN NOT INSPECT USING PLAN - NOT ENOUGH DETAIL. STOP WORK WILL BE ISSUED IF CONTRACTOR WORKING WITHOUT PERMIT. |