Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T06BU00320
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/30/2006 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :* | |
03/23/2006 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* | |
03/21/2006 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* 1. YOU DID NOT FOLLOW PLANS 2. YOUR 2X RIPPER ON BOTTOM OF OLD FASCIA ACCOMPLISHES NOTHING. 3. YOU NOW NEED TO ATTACH AN A3.5 CLIP AT EVERY EXISTING RAFTER TO OLD FASCIA AND 3-16d NAILS FROM OLD FASCIA INTO NEW RAFTER. 4. YOU NEED TO STAGGER JOINTS IN PLYWOOD AND NAIL 6" OC EDGES 12" OC FIELD |
|
03/17/2006 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* FRAME UP YOUR PORCH AND CALL FOR NEXT INSPECTION BEFORE YOU PUT ROOF PAPER ON. |