Permit: T06BU00201

Parcel: 108163970

Inspection Status: Approved

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
03/20/2006 POOL/SPA PRE-GUNITE Approved IVRS - Inspection :*
03/10/2006 POOL/SPA PRE-GUNITE Cancelled IVRS - RI canceled
03/08/2006 POOL/SPA PRE-GUNITE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REBAR OK
2) LOCATION NOT AS SHOWN ON PLOT PLAN
3) HAVE PLOT PLAN REVISED AND CHANGED LOCATION APPROVED
4) GROUND WIRES AND CONDUIT FROM EQUIPMENT TO POOL OK
03/07/2006 POOL/SPA PRE-GUNITE Cancelled IVRS - RI canceled