Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06BU00087

Parcel: 138133480


Addresses:

351 W HAMMERHEAD WY

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
01/26/2006 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
01/20/2006 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. YOU NEED TO HAVE LOOSE DIRT OUT OF FOOTING
2. YOU NEED TO INSTALL REBAR IN FOOTING
2 #4 (13MM) EACH WAY