Permit: T06BU00071

Parcel: 114473180


Addresses:

7231 E ASHLING LN

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/16/2006 FRAMING Approved IVRS - Inspection :*
03/08/2006 FRAMING Partial Approval IVRS - Inspection :*
1. NEED TO ADD 16D NAILS @ 16" O.C. (24" OC AS IS) @ (2) 2X10 LEDGER PER REVISED PLAN.
2. NEED TO SEE FRAMING FOR HARD LID -- ADDITIONAL FRAMING FOR HARD LID OR "DROPPED CEILING" NEEDS TO BE STRAPPED, NAILED, ETC. PER CODE.
3. NEED TO GET PERMIT FOR ANY ELECTRICAL WORK THAT WILL BE DONE
*ITEM: 01030 ROOF NAILING - APPROVED.
03/03/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 2X6 RAFTERS ARE NOT ATTACHED TO THE EXISTING 4X12 BEAM PER PLAN. THEY ARE ATTACHED TO (2) 2X10 ROUGHLY 2' AWAY FROM BUILDING. (2) 2X10 ARE ATTACHED TO THE EXISTING "WING WALLS" OF PATIO.
2. RAFTERS @ OPEN SIDE OF PORCH (W.SIDE) AREN'T ATTACHED DIRECTLY TO THE 4X10 BEAM. THEY ARE ATTACHED TO A 2X4 NAILED TO BEAM THE H2S STRAPS HAVE ONLY (2) NAILS ON 4X10 BEAM.
3. PLANS SHOULD BE REDRAWN & RESUBMITTED FOR REVIEW IF THIS CONSTRUCTION IS TO BE DONE.