Inspection Status: Approved
Inspection History: POOL/SPA ELECTRIC
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/19/2006 | POOL/SPA ELECTRIC | Approved | IVRS - Inspection :* | |
| 06/15/2006 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) THERE MUST BE A 5' BARRIER AT SOME POINT ON THE PROPERTY. THE WROUGHT IRON FENCE AT THE POOL SUFFICES FOR THE BARRIER BETWEEN THE HOUSE AND THE POOL BUT NOT TO THE OUTSIDE WORLD 2) THE LIGHT JUNCTION BOX MUST BE BONDED TO THE POOL EQUIPMENT AND POOL, NOT JUST WITH THE GROUND WIRE TO THE ELECTRIC PANEL |
|
| 06/14/2006 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PERIMETER WALL ENCLOSURE TO BE MINIMUM 5' HIGH DBL GATE TO BE PERMANETLY FIXED INTO CONCRETE SO AS OPENABLE GATE HAS PERMANENT LATCH POST 2) INSTALL ALL SVRS 3) STOPPED INSPECTION-INCOMPLETE |
|
| 02/08/2006 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* 1) CONDUIT AND BOND WIRES OK 2) BOND JUNCTION BOX FOR LIGHT 3) WIRES NOT RUN |