Permit: T06BU00050


Addresses:

412 E LIMBERLOST DR


Inspection Status: Approved

Inspection History: GRADING - FINAL

Permit Number - T06BU00050

Inspection Description - GRADING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/20/2008 GRADING - FINAL Approved
05/13/2008 GRADING - FINAL Partial Approval ALL SITE WORK NOT COMPLETED
04/22/2008 GRADING - FINAL Cancelled IVRS - AP canceled
04/03/2008 GRADING - FINAL Partial Approval THIS SITE HAS BEEN CHECKED FOR THE FINAL RELEASE OF THE ASSURANCES AND THE GRADING RESEEDING BONDS AND HAS BEEN FOUND TO BE INCOMPLETE AT THIS TIME. ADDITIONAL HOMES ON THIS SITE WILL HAVE TO BE CONSTRUCTED PRIOR TO THE FINAL RELEASE OF ALL BONDS AND ASSURANCES. THE SITE DOES NOT HAVE ALL OF THE SIDEWALKS, AND DRIVEWAYS TO ALLOW FOR THE FULL RELEASES AT THIS TIME. CONTACT DAVID ROBERTS AT 349-7643 TO ARRANGE FOR AN ON-SITE MEETING TO DISCUSS THE REMAINING ITEMS THAT WILL NEED TO BE COMPLETED PRIOR TO THE FINAL RELEASES. THE PREVIOUS INSPECTION SHOWN ON 3/6/2008 IS NULL AND VOID AT THIS TIME AND CAN ONLY BE CONSIDERED AS AN INSPECTION FOR THE INTERMEDIATE GRADING INSPECTION.
03/06/2008 GRADING - FINAL Approved SITE HAS TWO HOMES BUILT, ALL OTHE LOTS HAVE BEEN GRADED AND HYDROSEEDED. ALL COMMON AREAS, DRAINAGE WAYS AND RET/DET BASINS HAVE BEEN COMPLETED. ROADWAYS, CURBING, AND HC RAMPS HAVE BEEN INSTALLED.
RET/DET BASIN CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD HAS BEEN RECEIVED.

PHILL - CUTSHAW/YEAGER 661-4971
10/18/2007 GRADING - FINAL Denied 1) SEDIMENT CONTROLS HAVE BEEN INSTALLED AT ALL LOT DRIVEWAY ENTRANCES.
2) A CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD HAS BEEN SUBMITTED AND IS ON FILE WITH THE CITY OF TUCSON STATING THAT RETENTION BASINS ON SITE WERE BUILT IN ACCORDANCE WITH THE APPROVED PLANS.
3) DUE TO THE FACT THAT SIDEWALKS HAVE NOT BEEN INSTALLED AS SHOWN ON THE APPROVED GRADING PLAN, AND GRADED LOTS HAVE NOT BEEN STABILIZED PER DEV. STD 11-01 (EXCAVATING AND GRADING) THE GRADING PERMIT CAN NOT BE FINALED AT THIS TIME.
10/11/2007 GRADING - FINAL Denied MET WITH OWNER AND SUPERINTENDENT TO DISCUSS CLOSING OUT THE CURRENT GRADING PERMIT. PRIOR TO FINAL GRADING APPROVAL, PROVIDE THE FOLLOWING:

1) DRAINAGE CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD STATING THAT SURFACE DRAINAGE AND RET/DET BASINS ON SITE WERE CONSTRUCTED IN ACCORDANCE WITH THE APPROVED GRADING PLAN.
2) INSTALL SEDIMENT CONTROLS AT ALL CURB OPENINGS FOR EACH LOT STILL UNDER CONSTRUCTION UNTIL SITE IS BUILT-OUT.
3) PROVIDE A MATERIALS WASH OUT ON SITE FOR ONGOING CONSTRUCTION.
4) CONTINUE TO SWEEP UP ANY TRACKED SOIL OFF OF ROADWAYS AS NEEDED.