Inspection Status: Partial Approval
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/20/2006 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* 1. SOIL WATER TEST IS OK 2. ALL CORRECTIONS HAVE BEEN MADE 3. NOTE: SHALL PROVIDE APPROVED FEMALE COUPLINGS WITH PLUGS FOR ALL CLEAN OUTS 4. OK TO BACKFILL TRENCH. |
|
| 01/11/2006 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLEASE FOLLOW ALL NOTES LEFT FROM 1/9/06 INSPECTION INCLUDING HAVING RETEST ON SYSTEM AT TIME OF INSPECTION. HAVE ALL FITTINGS EXPOSED. |
|
| 01/09/2006 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999*SHALL PROVIDE L-SWEEPS ON HORIZONTAL TO HORIZONTAL DRAINAGE @ 2" ABS AND 4" NO HUB SHALL PROVIDE DIRECTIONAL FITTINGS FOR TWO WAY C.O @ REAR OF HOUSE CANNOT LOCATE A THREADED FITTING UNDERGROUND @ HCS CONNECTION USE A WYE AND PERM CAP SHALL PROVIDE A DIRECTIONAL FITTING FOR C.O @ KITCHEN DRAIN AND APPROVED C.O WITH PLUG RE TEST THE SYSTEM. |