Permit: T05PL02094

Parcel: 132162140

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/03/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
12/29/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
9.9 PSI
PRESSURE TEST ALL GAS PIPING, INCLUDING POOL HEATER
ALA GAS VALVE MUST INSTALLED AHEAD OF FLEX CONNECTOR
ALL EXPOSED HORIZONTAL PIPING MUST BE A MIN. OF 6" ABOVE GRADE
USE PIPE PRIMER AND WRAP TOOL MAKRS & FITTINGS BELOW GRADE
PROVIDE WEATHERPROOF SUPPORT ACROSS ROOF AT 8' AND AT CHANGES OF DIRECTION
AGA VALVES REQUIRED AT APPLIANCES.
BONDING OF GAS LINE REQUIRED
REPRESSURE TEST
RECALL FOR INSPECTION