Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/23/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* OK FOR GAS TO GUEST HOUSE CALL SW GAS TO MAKE CONNECTION |
|
| 01/12/2006 | PLUMBING - FINAL | Partial Approval | NEW REPLACEMENT GAS LINE TO GUEST HOUSE ONLY NEW LINE SUPPLING WATER HEATER, DRYER AND STOVE |
|
| 01/11/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 15 PSI 1027 PRESSURE TEST OK 2) PIPING IN GROUND-OK TO COVER 3) T & P DRAIN MUST TERMINATE OUTSIDE AND VERTICALLY WITHOUT THREADS. USE APPROVED MATERIAL PROVIDE 1" CLEARANCE AT B-VENT 4) CAP VALVES IF NOT CONNECTED TO APPLIANCES 5) RECALL FOR FINAL INSPECTION |