Permit: T05PL02088

Parcel: 122151840


Addresses:

2219 N CAMILLA BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/12/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
01/09/2006 PLUMBING - FINAL Cancelled CANCELLED PER CONTRACTOR AMY THOMPSON #572-2090
01/06/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/04/2006 PLUMBING - FINAL Not ready for Inspection PIPE HAS BEEN REMOVED FROM TRENCH
DO NOT CALL FOR INSPECTION UNTIL READY
YOU MUST CLARIFY YOUR ADDRESS, OR RISK NOT GETTING AN INSPECTION WHEN YOU'RE FINALLY READY.
01/02/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PLASTIC GAS PIPE REQUIRES 12" OF COVER AT ALL POINTS. REQUIRE CLEAN FILL OR SAND
2) BE SURE AND CLARIFY ADDRESS. THERE CANNOT BE TWO 2219 N. CAMILLA BLVD. BLDG ADDRESS TO MATCH PERMIT ADDRESS. THIS IS A MUST!!!
12/29/2005 PLUMBING - FINAL Cancelled CANCELLED PER PLUMBER JEFF #243-3607
12/29/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
12/28/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
12/23/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*PROVIDE A MIN. 10 LB TEST ON ENTIRE SYSTEM
VENT ON WATER HEATER MUST BE DOUBLE WALL PIPE, EXTENDED 2' ABOVE UPPER ROOF, WITH AN APPROVED CAP. MAINTAIN MIN. 1" FROM COMBUSTIBLES. RE INSTALL ENCLOSURE AROUND WATER HEATER.
PROVIDE A BOND JUMPER FROM ELEC. SERVICE TO WATER LINE & GAS LINE
PROVIDE AN APPROVED GAS SHUT OFF VALVE AT HEATER.
HOUSE IS AT REAR END OF PROPERTY BEHIND FRONT HOUSE.