Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/12/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 01/09/2006 | PLUMBING - FINAL | Cancelled | CANCELLED PER CONTRACTOR AMY THOMPSON #572-2090 | |
| 01/06/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/04/2006 | PLUMBING - FINAL | Not ready for Inspection | PIPE HAS BEEN REMOVED FROM TRENCH DO NOT CALL FOR INSPECTION UNTIL READY YOU MUST CLARIFY YOUR ADDRESS, OR RISK NOT GETTING AN INSPECTION WHEN YOU'RE FINALLY READY. |
|
| 01/02/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PLASTIC GAS PIPE REQUIRES 12" OF COVER AT ALL POINTS. REQUIRE CLEAN FILL OR SAND 2) BE SURE AND CLARIFY ADDRESS. THERE CANNOT BE TWO 2219 N. CAMILLA BLVD. BLDG ADDRESS TO MATCH PERMIT ADDRESS. THIS IS A MUST!!! |
|
| 12/29/2005 | PLUMBING - FINAL | Cancelled | CANCELLED PER PLUMBER JEFF #243-3607 | |
| 12/29/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 12/28/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 12/23/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*PROVIDE A MIN. 10 LB TEST ON ENTIRE SYSTEM VENT ON WATER HEATER MUST BE DOUBLE WALL PIPE, EXTENDED 2' ABOVE UPPER ROOF, WITH AN APPROVED CAP. MAINTAIN MIN. 1" FROM COMBUSTIBLES. RE INSTALL ENCLOSURE AROUND WATER HEATER. PROVIDE A BOND JUMPER FROM ELEC. SERVICE TO WATER LINE & GAS LINE PROVIDE AN APPROVED GAS SHUT OFF VALVE AT HEATER. HOUSE IS AT REAR END OF PROPERTY BEHIND FRONT HOUSE. |