Permit: T05PL02051

Parcel: 134042760


Addresses:

8947 E MILLETT DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/21/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
PETITION OF APPEAL #2005.290 ON SITE
18 PSI TEST UNDERGROUND UP AT BUILDING TO FIREPLACE LOG LIGHTING, WATER HEATER & FURNACE ONLY - OK
S.W. GAS 889-1888 - GAS CARD @ METER
12/20/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*PIPING IN GROUND OK TO COVER, PRESSURE TEST HOLDING 20 PSI
BONDING REQUIRED ON GAS LINE
T & P RELIEF VALVE MUST GRAVITY DRAIN TO EXTERIOR
XL T & P REQUIRE IF PIPED W/TEE ABOVE HEATER.
PIPE ON ROOF REQUIRED WEATHER PROOF SUPPORTS @ 8'
?? FURNACE FLUE SHALL TERMINATE 1' ABOVE GRAVITY AIR INLET.
REMOVE OLD PLUG COCK TO FIRE PLACE
LOG LIGHTER REQUIRES VALVE TO REACH AB/? FROM LIGHTING AREA
RETEST SYSTEM AFTER MAKING CORRECTIONS
RE CALL FOR INSPECTIONS.
12/19/2005 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*