Permit: T05PL02013

Parcel: 135020110

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/20/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
12/16/2005 PLUMBING - FINAL Not ready for Inspection 03050 - 10 PSI TEST NEW PIPING UNDERGROUND UP AT BUILDING TO FURNACE, WATER HEATER, DRYER (ONLY)
03090 - 1. PROVIDE 3-GALV SCREWS AT JOINT FROM SINGLE TO DOUBLE WALL CONNECTION AT FURNACE.
2. PROVIDE PIPE AT PENETRATION THRU FURNACE HOUSING
3. PROVIDE MINIMUM 1" CLEARANCE FROM WATER HEATER FLUE VENT AND COMBUSTABLES
4. PROVIDE MINIMUM 100 SQ INCH UPPER COMBUSTION AIR OPENING FOR WATER HEATER
5. PROVIDE CORRECT BONDING OF BUILDING GAS PIPING.
12/15/2005 PLUMBING - FINAL Denied